pharma | medicine

INDUSTRIES

sterilized + dried = PERFECTLY PREPARED

Residual moisture often remains after sterilisation, leading to increased false reject rates, process interruptions and the associated additional costs.
The GESETE PHARMA | line delivers maximum drying results with minimum space requirements and reliable process reliability.

3 SYSTEMS – Optimized for your containers

With the GESETE PHARMA | line, we offer three specialized systems tailored to typical pharmaceutical containers—for maximum process reliability, energy efficiency, and product quality.

<99,95%

residual water removal

– hygienic design
– controlled water drainage

~2,5 m²

smallest footprint

– high system availability
– low maintenance requirements

7.5 – 15 kW

max. energy demand

– low energy costs
– process monitoring

75-82dB(A)

quiet operation

– enhanced sound reduction
– process-reliable adjustment unit

IV-BAGS

 

The integrated and patented OMEGA blow-off process ensures uninterrupted 360° blow-off. It minimizes false rejection rates by downstream inspection systems such as leak detection or visual camera systems. In addition, it reliably prevents water carryover into downstream labeling or cartoning processes.

smallest footprint
for 100 bags/min, single lane maximum 2.5 m²

low energy consumption
11 kW – max. 15 kW, low OPEX

low installation effort
each system is adjusted to the products during the FAT.

VIALS, BLOW-FILL-SEAL (BFS) BOTTLES
AND INFUSION BOTTLES

 

Compact complete system for retrofitting to existing lines or optionally with integrated conveyor belt. Minimizes false rejection rates by subsequent inspection systems such as leak detection or visual camera systems.

smallest footprint
for 10,000 bottles/hour, single lane maximum 1.8 m²

low energy consumption
7.5 kW – max. 15 kW, low OPEX

low installation effort
each system is adjusted to the products during the FAT

BLOW-FILL-SEAL (BFS) AMPOULES

 

Compact complete system with integrated conveyor technology. Minimizes false rejection rates by subsequent inspection systems such as leak detection or visual camera systems. Optionally available feed unit speeds up manual feeding processes and allows valuable buffer times.

smallest footprint
example: 100 strips/min, approx. 1.5 m²

low energy consumption
4 kW – max. 11 kW, low OPEX

low installation effort
each system is adjusted to the products during the FAT

Send us your URS—we will advise you personally and work with you to develop the optimal solution for your project